<?xml version="1.0" encoding="iso-8859-2"?>
<zprava jazyk="en" cislo="31/2006">
  <nazev>FlowMon Probe</nazev>
  <autor>Pavel Čeleda, Milan Kováčik, Tomáš Koníř, Vojtěch Krmíček, Petr Špringl, Martin Žádník</autor>
  <datum>21.12.2006</datum>

  <h1>Abstract</h1>
  <p>The objective of this technical report is to describe hardware
  and software activities during the development of FlowMon
  probe. FlowMon probe is second phase of IP flows monitoring project
  originally inspired by NetFlow. Its first phase was a proof of
  concept which showed feasibility to implement IP packet monitoring
  in board with FPGA and higher functionality such as exporting
  flow-records in host PC.  Today the FlowMon probe is ready to use
  but still some improvements are in progress. In near future we would
  like to support various mix of features.  For example adaptive
  sampling, large flow-cache, variable flow-record, web front-end.</p>

  <p><b>Keywords:</b> FlowMon, NetFlow, FPGA, Liberouter</p>

  <h1 id="introduction">Introduction</h1>
  <p>The project started two years ago and its goal was to create an
autonomous network probe which gathers important data about network
traffic. Our inspiration was the NetFlow implemented by Cisco. It
provides aggregated information about IP flows which could be used to
manage current networks, plan new topologies or detect DoS attacks, also
for billing and accounting.  Standalone dedicated device for such type
of monitoring has several benefits. For example it is not necessary
to change routers that do not support NetFlow.
Also the probe has high performance and flexibility in means of
various enhancements to protect itself against malicious traffic.
These countermeasures (proposed in
<cite href="EV03"/>) are missing even in the state-of-the-art routers.</p>
  <p>Today the phase one <cite href="CEL05"/>, <cite href="ZAL05"/> is stable and distribution
packages are available for download at the <a href="http://www.liberouter.org/clients/">Liberouter</a> web site. The phase one
is successfully used to monitor networks by our GEANT2 partners such as
SURFnet, SWITCH, ISTF (monitoring whole
Bulgarian NREN), etc.  Phase one is running on older type of COMBO
cards, COMBO6 mother card and COMBO-4MTX add-on card. These cards
are now being replaced by much more powerful version of COMBO6X mother
card and COMBO-4SFPRO add-on card which are used as a new platform for
FlowMon probe.  Therefore we consider the phase one to be finished
but we will still continue with its support in terms of bug fixes or
minor improvements.  The rest of the paper is focused on the phase 2 -
FlowMon probe.</p>
  <obr src="combo6x">COMBO6X - PCI-X 64/66MHz hardware accelerated card</obr>
  <p>The FlowMon probe works as a T-splitter and when inserted in a line  it
is fully transparent for all network traffic. IP flows are monitored by
FPGA <i>(Field Programmable Array)</i> chip and stored in on-board external
memories. Expired flow-records are forwarded to upper
software layers.  User space application sends them to collector.</p>
  <obr src="flowmon_collector">Probe inserted in line and sending data to collector.</obr>
  <p>The report is organised as follows. <a href="#flowmon-probe-structure">Section</a> describes an abstract view
of the FlowMon probe. Next two sections then give the details about
firmware and software. Following sections enumerate FlowMon probe
capabilities and results of testing FlowMon probe with various NetFlow
collectors. Finally, further improvements and plans are discussed.</p>
  <h1 id="flowmon-probe-structure">FlowMon probe structure</h1>
  <p>The whole system of the FlowMon probe consists of two parts - hardware
and software. The hardware part is intended for processing of incoming
packets on high speed (wire speed) while the software together with
ordinary network card are utilized as a transmitter of flow-records.
Time critical monitoring has to be implemented on the
adapter card, on the other side complex implementation of NetFlow
protocol is done in software. This distribution of tasks allows fast upgrades
every time when new export format is deployed.</p>
  <p>The system could be divided into several layers with specific
  tasks (see <a href="#fig3">Figure</a>).</p>
  <obr id="fig3" src="flowmon_layers">FlowMon probe layers</obr>
  <p>
    <b>Description of FlowMon probe layers</b>
  </p>
  <ul>
    <li>
      <p>Physical layer - process the L1 layer.</p>
    </li>
    <li>
      <p>Packet Header Parsing - extracts important data from packets on L2 and L3
layer.</p>
    </li>
    <li>
      <p>Metering - gather information about IP addresses, port numbers, protocols,
number of bytes and packets, start and end timestamps and other header fields.</p>
    </li>
    <li>
      <p>Driver - provides interface to load firmware, set parameters of metering process
and transport flow-records from the card to the PC.</p>
    </li>
    <li>
      <p>Anonymization - modifies IP addresses to keep users privacy.</p>
    </li>
    <li>
      <p>Filter - defines which flow record is send to given collector.</p>
    </li>
    <li>
      <p>Flow Exporter - encapsulates flow records in NetFlow v5 or NetFlow v9 packet
and sends it to collector.</p>
    </li>
  </ul>
  <h1 id="flowmon-probe-firmware">FlowMon probe firmware</h1>
  <p>The firmware is composed of several units which are chained in
processing pipeline. Phase one showed us bottlenecks of the previous
design.  Therefore some parts of the packet processing pipeline is
instantiated multiple times. It allows to increase the throughput to be sufficient
to process all packets no matter of what size at full wire speed. At first
the packet header parsing pipeline is described and then the metering part.</p>
  <obr src="packet_parsing">Packet header parsing pipeline</obr>
  <p>Incoming packets from network interface are entering the <i>Input Buffer
(IBUF)</i> block. For each incoming packet the CRC <i>(Cyclic Redundancy
Check)</i> checksum and packet length (up to 8192 bytes) is checked and
only valid packets pass through. Valid packets are subject of optional
sampling. Sampling rate can be set from 1:1 (take every packet) to
1:65535. Periodic, random and byte sampling are implemented. Timestamp
(resolution 640 ns) is assigned to sampled packet and packet is sent for
further analysis.</p>
  <p>Input buffer was redesigned to be able to handle  short packets at full
gigabit speed. Older version was not able to handle burst of packets and
therefore a lot of them were dropped randomly or high sampling rate had to be
set.</p>
  <p>Packets with assigned timestamp are processed by <i>Header Field Extractor
(HFE/GENA)</i>. The HFE2 is a processor based on RISC <i>(Reduced Instruction
Set Computer)</i> architecture controlled by specific instruction set
intended for stream analysis. The processor core is called GENA
<i>(GEneric NAnoprocessor)</i> and with its peripherals and program for
FlowMon it is able to handle one million packets per second. Two HFE2
are instantiated per one interface to process full gigabit with no
packet loss. The extracted structure is called <i>Unified Header (UH)</i>
and is  stored in <i>Unified Header FIFO</i> temporarily.</p>
  <p><i>UH driver (UHDRV)</i> manage reading of unified headers out of the FIFOs.
The policy of management is round-robin. UHDRV transfers UH to the
metering part.</p>
  <obr src="monitor">Metering pipeline</obr>
  <p>At the input of metering part data are duplicated into two paths
(control and data path). Data path consists of <i>Statistic FIFO
(STATFIFO)</i> which stores the UH until is processed by <i>Storage (STO)</i>.
The control path begins with <i>Hash Generator (HGEN)</i> which computes
64-bit CRC from the fields which designates the flow. Part of the CRC is
used as an address in <i>Hash Search (HSRCH)</i>. Hash Search role is to look-up if
the record is already in the memory a give a pointer to the flow memory.
Using the pointer <i>Manager</i> checks a time-record of the flow. Finally
the flow-record is created or updated in <i>Storage (STO)</i>. If the flow
expires its record is deleted and transfered to <i>Software Output Buffer (SW
OBUF)</i> where it waits till it is read by driver.</p>
  <h1 id="flowmon-probe-software">FlowMon probe software</h1>
  <p>The software for FlowMon probe consists of several parts - kernel driver,
user space libraries, configuration programs and flow exporters.</p>
  <obr src="sw_layers">FlowMon probe software layers</obr>
  <p>The FlowMon kernel driver for COMBO6 and COMBO6X cards supports latest
2.4 and 2.6 Linux kernels. The configuration of the driver sources is
standalone, but the configured Linux kernel source tree must be present
to proceed a successful compilation. The configuration script is
available for the user to make the driver configuration easy.</p>
  <p>The libcsflow library was designed as a middle layer between exporter
applications and kernel driver. It hides specific system calls and
provides the standard interface in C language. The future improvements
will be to move more common code like the NetFlow record parsing to this
library from exporter application.</p>
  <p>The configuration programs are used for loading and initializing the
FlowMon probe firmware into COMBO cards after kernel drivers are loaded.
Main configuration programs are <tt>csxtool(1)</tt> for firmware loading and
<tt>flowmonctl(1)</tt> tool for initialization routines. The routines are
initialization of hardware units UHDRV and HGEN, loading program to HFE
processor and settings timeouts, sampling rate and starting up the whole
probe.</p>
  <p>The flow exporter is a basic data exporting tool in NetFlow v5 and v9
format. It is written in C to support the COMBO6 and COMBO6X cards with
NetFlow extension. It communicates with a collector via the IPv4 or IPv6
protocol using UDP protocol.</p>
  <p>A set of shell scripts can be used for configuring and starting up the
FlowMon probe. These scripts call programs like <tt>csxtool(1)</tt> and
<tt>flowmonctl(1)</tt> and check any unexpected situations. User only set
several constants which say how to configure the probe. The script loads
right drivers. Detects which COMBO cards are installed in computer and
according that it will load right firmware into FPGAs. Then calls
<tt>flowmonctl(1)</tt> and initialize firmware and starts it up. Active and
inactive timeouts are set according parameters of the script.
Flow exporter is activated and exporting data to specified collector.</p>
  <h1 id="flow-export-program">Flow export program</h1>
  <p>Because of some problems with our first version of data exporting
program we proposed and implemented new <tt>flowmon_nf5,9 (1)</tt> program.
FlowMon is a modular NetFlow v5 and v9 data exporting tool. It is written
in pure C language to support COMBO6 and COMBO6X mother cards with
NetFlow extension. It uses IPv4 or IPv6 for communication with
independent NetFlow collector.</p>
  <p>
    <b>Structure and functions</b>
  </p>
  <p>FlowMon is designed as modular system and contains four basic parts. The
first supervising module maintains all other modules and controls the
flow processing. The next two modules are designed for reading flows and
made some additional work (filtering and anonymization). Last part is
responsible for creating and sending NetFlow datagrams. The supervising
module parses the command line options, calls init functions for all
modules and handle errors. The basic algorithm is really simple.
With all modules enabled, FlowMon works in infinite loop (until
terminated):</p>
  <pre>init_main_part
init_hardware
init_addons      /* filtering, anonymization */
init_exporter    /* v5 or v9, depends on executable name */

loop_begin
        if &lt;read_flow_from_hw&gt;
                if &lt;test_filter&gt;
                        do_anonymization
                        add_to_export
                fi
        fi
loop_end</pre>
  <p>The flow reading module is now designed to support only COMBO cards, but
may be extended in future to support other flow sources. The module
contains two parts. One for testing hardware availability and hardware
initialization. Second for continuous reading of the flows from hardware
and transmitting them to supervising module. The basic algorithm is
described below.</p>
  <pre>begin init_hw
        test_hw_present
        init_hw
end

begin read_hw
        get_flow
        if_not_error
                fill_independent_flow_struct
                return_flow
        else
                return_error
        fi
end</pre>
  <p>The exporting module is splitted into two independent modules for
NetFlow v5 and v9. The both modules do the similar work. Collects flow
until packet size is reached and than send packet to collector.  NetFlow
v5 module only fills packet and sends it to collector. NetFlow v9 module
is watching if timeout or packet counter is reached and than sends the
v9 templates to collector.  The templates are fully configurable using
simple configuration file, described in user documentation.</p>
  <p>The basic algorithm of NetFlow v9 exporting module:</p>
  <pre>begin init_v9
        create_collector_connection
        init_templates
        add_templates_to_send
end

begin process_v9
        find_best_template_to_use
        fill_template_data
        add_data_to_send
        if &lt;packet_size_reached&gt;
                send_packet
                if &lt;template_refresh_interval_reached&gt;
                        add_templates_to_send
                fi
        fi
end</pre>
  <p>The last part are add-on modules. These modules are designed to do some
middle work, like flow mangling, filtering etc. Following modules are
available:</p>
  <p>
    <b>Filter module</b>
  </p>
  <p>The FlowMon filter is a basic interval matching implementation related
to network addresses. It works for both IPv4 and IPv6 (actually, each IP
protocol family has own filter). Current filter storage is a
list. This fact implies poor performance for large filters. But the
filtering framework allows to implement storage more effectively -
addresses are being converted into "integers" in host byte order (for
IPv6 this means a 16 byte unsigned "long long long int") and a couple of
macros dedicated to compare those integers are provided too. This makes
it possible to replace storage back ends independently of the stored data.</p>
  <p>
    <b>Anonymization module</b>
  </p>
  <p>Anonymization module is designed to hide original data source
information, like IP addresses and port numbers. Currently supported are
two modes basic and AES <i>(Advanced Encryption Standard)</i>. Basic module
only masks IP address to defined address range (default is
192.168.0.0/16) and works only for IPv4 flows. AES anonymization module
applies AES block cipher to selected fields (IP address, port numbers) to
do total anonymization. Cipher may be initialized using zero string or
current system time to provide better security level. Fields which will be
anonymized are configurable. Supported fields are source and
destination addresses and ports. This module is IP version independent
and is able to to anonymize IPv4 as well as IPv6 flows.</p>
  <h1 id="flowmon-probe-capabilities">FlowMon probe capabilities</h1>
  <p>The phase one helped us to localize the bottlenecks of the
original design. Many problems were discovered during tests on real
network. Such as old input buffers were unable to handle packets
with short preamble, or packets which arrived in intensive burst. Further
the old HFE had poor performance to process larger amount of packets per second.
Therefore the new HFE/GENA was
created and instantiated two times per one interface.</p>
  <p>HW parameters of FlowMon probe:</p>
  <ul>
    <li>
      <p>monitoring of two gigabit ports at full speed</p>
    </li>
    <li>
      <p>precise timestamp, active and inactive timeouts</p>
    </li>
    <li>
      <p>standard sampling, sample and hold</p>
    </li>
    <li>
      <p>repeater and splitter ports</p>
    </li>
  </ul>
  <p>SW parameters of FlowMon probe:</p>
  <ul>
    <li>
      <p>export in NetFlow v5, v9</p>
    </li>
    <li>
      <p>anonymization and per collector filtering</p>
    </li>
  </ul>
  <h1 id="testing-with-netflow-collectors">Testing with NetFlow collectors</h1>
  <p>During development of FlowMon probe, we have used different collectors
to collect and store exported NetFlow data from FlowMon probe. The
main effort was focused on <a href="http://nfsen.sourceforge.net">NfSen collector</a>, but we tested and
used FTAS collector <cite href="FTAS"/> and <a href="http://www.ntop.org">Ntop</a> as well.</p>
  <p>Important set of features, which should be supported by collector:</p>
  <ul>
    <li>
      <p>ability to process NetFlow version 5 and NetFlow version 9 datagrams,</p>
    </li>
    <li>
      <p>process NetFlow data at high speeds,</p>
    </li>
    <li>
      <p>well arranged graphical output of measured data,</p>
    </li>
    <li>
      <p>possibility to process historical NetFlow data.</p>
    </li>
  </ul>
  <p>
    <b>NfSen collector</b>
  </p>
  <p>NfSen collector is a graphical web based front end for the <a href="http://nfdump.sourceforge.net">NFDUMP</a>
- tool for collecting and storing NetFlow data. The main advantages of
this collector are well arranged output of the most important
network traffic characteristic, storing data in RRD <i>(Round Robin
Database)</i>, possibility of detailed processing of NetFlow data during
specified time period, working with user defined profiles and powerful
filtering of NetFlow data based on various characteristics.</p>
  <p>We are using this collector for more then a half year, so after longer
period of testing we can say that NfSen together with FlowMon probe
works without any problems. This is also our preferred collector, when
we deploy FlowMon probe to external testers.</p>
  <obr src="nfsen1">NfSen preview page</obr>
  <obr src="nfsen2">NfSen detail page</obr>
  <p>There are some things, which need to be mentioned. At the side of
collector, actually a support of sampled NetFlow data and correct
displaying of them is not implemented.</p>
  <p>
    <b>FTAS collector</b>
  </p>
  <p>FTAS <i>(Flow-Based Traffic Analysis System)</i> is an experimental traffic
analysis system which aims to give both short-term and long-term view
at network traffic. It is database based solution and for displaying of
gained data users need to run queries on a database. It has a powerful
filtering tool and all processed queries could be visualized by a
several types of graphs.</p>
  <p>We have used this solution at the first phase of developing and testing
FlowMon probe, but in these days FTAS doesn't have capabilities for
displaying aggregated longer term statistics (e.g. average traffic
during some period), so we decided to use NfSen.</p>
  <p>
    <b>Ntop</b>
  </p>
  <p>Ntop is an advanced tool for analysis of network traffic, based on Linux
libpcap library. Via web based front end it displays a current state of
network and with special extending module for NetFlow it is enabled to
process NetFlow data.</p>
  <p>During our tests with this collector we have found out that the big
advantage of this solution is almost real time displaying of NetFlow
data. On the other hand, problem was with processing of NetFlow version 9
data, which Ntop NetFlow extension module doesn't support correctly.</p>
  <h1 id="future-improvements">Future improvements</h1>
  <p>When comparing phase one and FlowMon, most improvements were focused to
increase throughput of firmware design or to make software transparent
and modular.  As these goals were already achieved we would like to
extend capabilities in other directions.</p>
  <p>First of all adaptive sampling at the network interface will be added.
Such type of sampling guarantees optimal resource utilization through
various traffic mix. There are two parameters
(packets per second and memory utilization) according to which the
adaptation takes place. The adaptation function is implemented as a
look-up table. Each row contains lower and upper boundary of parameters
and the sampling rate. The unit works as follows:</p>
  <ul>
    <li>
      <p>The table is initialized by software.</p>
    </li>
    <li>
      <p>Row-pointer is set to zero, which means that row zero is currently
addressed.</p>
    </li>
    <li>
      <p>Input parameters are compared with lower and upper boundaries.</p>
    </li>
    <li>
      <p>If parameters exceeds lower/upper boundary given in the row
then the row-pointer is decremented/incremented and thus new sampling
rate is selected. Go to previous point.</p>
    </li>
  </ul>
  <p>Note that it is up to user how to initialize the table. But it is
recommended that he keeps certain hysteresis when setting the
boundaries. So the row-pointer remain steady for longer time after
change.</p>
  <obr src="hysteresis">Hysteresis of boundaries</obr>
  <p>Next extension will address the issue of huge amount of active flows.
Today the FlowMon probe is able to keep 64000 simultaneous flows which
is insufficient for large scale networks. Therefore it is planned to
change SSRAM (4MB) memories for SDRAM (512MB). Unfortunately SDRAM
memories have longer delay between data request and data acquisition.
The delay can be shortened using two level system of cache and SDRAM.
The success of such an approach depends on a deep understanding of the
dynamical characteristics of the incoming data. In the case of network
traffic the most important property is temporal
correlation (locality). To this end, our simulation and verification
group performed measurements on traffic samples taken from several
points in the CESNET backbone and Brno campus network in order to do
realistic estimates for the temporal locality of the typical network
traffic. The parameter of interest is the flow gap, i.e., the number of
foreign packets between two packets of the same flow. You can find more
about their work in <cite href="KRA06"/>. The results of their work will be utilized
in a new memory-efficient design of the FlowMon probe.</p>
  <p>The improvements will also focus on flexibility of flow record. To this
end, the firmware flow record is static which was enough for protocol
NetFlow v5, but is too constraining for new protocols like NetFlow v9 or
newly standardized IPFIX. This is maybe the most tricky extension as it
requires to implement whole framework to coordinate firmware and
software parts.</p>
  <obr src="varflowrecord">Framework structure for variable flow record.</obr>
  <h1 id="conclusion">Conclusion</h1>
  <p>The FlowMon probe is tested on the access link connecting the Brno
Academic Computer Network to the CESNET2 backbone and CESNET backbone in
Prague. The results collected by NfSen and FTAS are very promising.</p>
  <p>Supported platforms are COMBO6X with COMBO-4SFPRO and COMBO6X with
COMBO-2XFP. The FlowMon firmware now works at 100 MHz, which results in
the theoretical maximum throughput of 3.2 Gb/s. This improvement was
achieved mainly by duplicating the input processing part and using new
input buffers and new HFE2 (GENA). These goals were stated in our
technical report last year and were successfully fulfilled. So today we
are able to monitor two gigabit interfaces at wire speed no matter of
packet size.</p>
  <p>The flow cache currently has room for 64 thousand flows but this
capacity will soon be increased to 256 or 512 thousand flows. The almost
ten-fold increase in flow cache capacity should allow to monitor all
flows with higher precision and to absorb parts of DoS attacks.</p>
  <p>Our plans concerning the firmware are to enhance the design in the
direction of network traffic adaptivity, memory efficiency and IPFIX
compliance by means of supporting variable record format.</p>
  <h1 id="references">References</h1>
  <seznamknih>
    <kniha id="CEL05">Čeleda P., Kováčik M., Krejčí R., Kysela J., Špringl P.:
<i>Software for NetFlow Monitoring Adapter.</i>
Technical report <a href="http://www.cesnet.cz/doc/techzpravy/2005/netflow">33/2005</a>, Praha: CESNET, 2005.</kniha>
    <kniha id="EV03">Estan C. and Varghese G. New directions in traffic
measurement and accounting.
In: <i>Proc. ACM Transactions on Computer Systems (TOCS)</i>,
ACM, 2003, p. 270-313.</kniha>
    <kniha id="FTAS">Košňar T. <i>Flow-Based Traffic Analysis System - Architecture
Overview</i>, Technical report <a href="http://www.cesnet.cz/doc/techzpravy/2004/ftas-arch/">15/2004</a>, Praha: CESNET, 2004.</kniha>
    <kniha id="KRA06">Kramáreková M., Jakubík D., Žádník M. and Šafránek D.:
<i>Modelling, simulation and analysis of packet localization in time.</i>
Technical report <a href="http://www.cesnet.cz/doc/techzpravy/2006/netmix">32/2006</a>, Praha: CESNET, 2006.</kniha>
    <kniha id="RFC3917">Quittek J. et al. Requirements for IP Flow Information
Export. <a href="http://www.ietf.org/rfc/rfc3917.txt">RFC 3917</a>, IETF, 2004.</kniha>
    <kniha id="ZAL05">Žádník M., Lhotka L.: Hardware-Accelerated NetFlow Probe,
Cesnet technical report <a href="http://www.cesnet.cz/doc/techzpravy/2005/nflowhw">32/2005</a>, Praha: CESNET, 2005.</kniha>
  </seznamknih>
</zprava>